On most Whirlpool-built dryers, a blown thermal fuse stops the dryer from running or heating. It is a small safety part that costs little, but it blows for a reason, usually a clogged vent. This guide covers the 7 Whirlpool and Maytag thermal fuse and cut-off numbers we track, how to find yours, and what to check before you fit it.
The same parts are used in Maytag, Amana, Roper, Crosley, KitchenAid and many Kenmore dryers, because Whirlpool built them.
Whirlpool thermal fuse part numbers, most bought first
Share of estimated Amazon sales across all 7 numbers. Open a part to compare every replacement and search its full model list.
The thermal fuse on the blower housing of most Whirlpool-built dryers, electric and gas, and by far the most bought. Replaces 3388651 and 694511. When it blows, the dryer usually will not run at all.
21 listings from 13 brands, including Whirlpool's own part. Most-bought aftermarket: BlueStars, Seentech, HXMLS.
Compare WP3392519 replacementsA thermal cut-off kit (cut-off fuse plus high-limit thermostat) for many Whirlpool and Kenmore electric dryers. Replaces 3977393 and 3399848.
3 listings from 3 brands, including Whirlpool's own part. Most-bought aftermarket: BlueStars, Seentech. Fits 27 listed models, for example LEC6858AQ3, LEG8858JZ0, LER5636EZ01, LER8875EQ1.
Compare 279816 replacementsA cycling thermostat for many Whirlpool-built dryers; sellers often bundle it with the 3392519 fuse.
3 listings from 3 brands, including Whirlpool's own part. Most-bought aftermarket: Blutoget, Seentech. Fits 38 listed models, for example CET9100GQ0, CSP2940HQ0, WED5100HC0, WED5100HC1.
Compare 279973 replacementsA thermal cut-off kit for older Whirlpool and Kenmore dryers such as the LE-series models.
3 listings from 3 brands, including Whirlpool's own part. Most-bought aftermarket: Seentech, Aspen Pet. Fits 29 listed models, for example LE3000XSWO, LE5700XSNW, LE5800XSN3, LE7800XSN2.
Compare 279769 replacementsA thermal cut-off fuse for newer Whirlpool and Maytag dryers such as the WED4950, WED7000 and MEDC465.
2 listings from 2 brands, including Whirlpool's own part. Most-bought aftermarket: Southeast Specialties. Fits 4 listed models, for example MEDC465HW0, WED4950HW0, WED7000DW2, WED7300DW0.
Compare W10900067 replacementsA thermal cut-off kit for Maytag dryers such as the MED6000; sellers list it with thermostat 8557403 and fuse 8318314.
3 listings from 3 brands, including Whirlpool's own part. Most-bought aftermarket: Seentech, Edgewater Parts. Fits 124 listed models, for example MED6000XG0, MED6000XG1, MED6000XG2, MED6000XR0.
Compare 280148 replacementsA 195°F thermal fuse for many newer Whirlpool and Maytag dryers such as the WED5100 and MEDB835. Replaces W10693363.
2 listings from 2 brands, including Whirlpool's own part. Most-bought aftermarket: Supplying Demand. Fits 125 listed models, for example MEDB835DW3, WED5100HC0, WED5100HC1, WED5100HW0.
Compare W10909685 replacements
Thermal fuse or thermal cut-off?
Whirlpool-built dryers use two kinds of one-time safety fuse. The thermal fuse sits on the blower housing; when it blows, most models will not run at all. The thermal cut-off sits on the heater housing of electric dryers; when it blows, the dryer runs but gives no heat. Both are replaced, never reset.
How to find the right part number
- Read the model number. On most Whirlpool-built dryers the tag is inside the door opening. Each part page lists models where we have them.
- Read the old fuse. The part number or temperature rating is printed on the fuse body.
- Match the temperature rating. Fuses are rated for a specific temperature; never fit one with a different rating.
Find out why it blew
Unplug the dryer, and turn off the gas on a gas model, before you open it.
- Clean the vent. A clogged or crushed exhaust vent is the usual cause. Clean the whole run to the outside, not just the lint screen.
- Test the fuse. With the wires off, a good fuse shows continuity on a multimeter; a blown one shows an open circuit.
- Never bypass it. A jumper wire in place of a fuse removes the protection against a dryer fire.
Whirlpool's own fuse or an aftermarket one?
Across these 7 part numbers, Whirlpool's own listings make up 7% of estimated Amazon sales (May to September 2026). The rest goes to 15 aftermarket brands, led by BlueStars, Seentech and HXMLS.
Aftermarket fuses are usually sold in multi-packs. Check the temperature rating and terminals against your old fuse, and check that the listing names your dryer model.
Frequently asked questions
What is the most common Whirlpool dryer thermal fuse?
By estimated Amazon sales, WP3392519 is the most bought, at about 93% of sales across the 7 Whirlpool and Maytag fuse and cut-off numbers we track.
Do Maytag dryers use the same thermal fuse as Whirlpool?
Many newer Maytag dryers do, because Whirlpool builds them. Older Maytag-designed dryers use Maytag numbers such as the 280148 kit. Check your model number.
Why does my dryer keep blowing the thermal fuse?
Almost always because the dryer is overheating, usually from a clogged or crushed vent. Clean the full vent run and check the cycling thermostat before fitting another fuse.
As an Amazon Associate I earn from qualifying purchases. Sales shares are our estimates of Amazon sales and are rounded. Aftermarket parts are made by third parties, not by Whirlpool. How this works
All thermal fuse part numbers · All Whirlpool parts · All guides